Voltage and Continuous, Short-Time, and Fault-Closing Ratings
- Mastertrol Mark V Installation Manual Pdf
- Mastertrol Mark V Installation Manual Transfer Switch
- Mastertrol Mark Ii
- Mastertrol Mark V Installation Manuals
ATAS-100 Installation manual.zip: 209 Kbytes: ATAS-120 Operation manual.zip. FT-1000MP-Mark-V Service manual.zip: 116.174 Kbytes: FT-1000MP-Mark-V Technical. Installation Instructions. The Motor Switch Terminal, Model MST, is a 24 Volt. Ultrasound Ge Logiq 400 Md Manual more. MOTOR TERMINALS ON MASTERTROL MARK IV, V, VII, VIII, X, XXX, AND XXXI. Invertebrate Zoology Lab Manual.
kV | Amperes, RMS | |||||
---|---|---|---|---|---|---|
Nom. | Max | BIL | Cont. | Short-Time | Fault-Closing, Duty-Cycle, One-Time | |
Mom. | 3-Second | |||||
34.5 | 38 | 200 | 1200 | 61 000 | 40 000 | 30 000 |
46 | 48.3 | 250 | 1200 | 61 000 | 40 000 | 30 000 |
69 | 72.5 | 350 | 1200 | 61 000 | 40 000 | 30 000 |
115 | 121 | 550 | 1200 | 61 000 | 40 000 | 30 000 |
138 | 145 | 650 | 1200 | 61 000 | 40 000 | 30 000 |
1600♥ | 70 000 | 43 750 | 40 000 | |||
2000♥ | 80 000 | 50 000 | 40 000 | |||
161 | 169 | 750 | 1200 | 61 000 | 40 000 | 30 000 |
230 | 242 | 900 | 1600 | 70 000 | 43 750 | 40 000 |
2000 | 80 000 | 50 000 | 40 000 | |||
345 | 362 | 1300 | 1600 | 70 000 | 43 750 | 40 000 |
2000 | 80 000 | 50 000 | 40 000 |
♥ 1600 and 2000 amperes continuous available in Three-Pole Center-Break style only.
Interrupting Current Ratings for Transformer Switching and Protection
Mastertrol Mark V Installation Manual Pdf
Class | Qualifications | Maximum Amperes, Interrupting RMS Symmetrical |
---|---|---|
Parallel Switching | Max 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS | 1200/1600/2000♥ |
Load Dropping and Magnetizing Current Switching | Transformers connected to solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side | 1200/1600/2000♥♣ |
All other connections of transformers | 1200/1600/2000♥♣ | |
Fault Interrupting | Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than ♠. | 7000 or 8000 |
Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher less than ♠. | 4000 (3000A for 115-kV single-gap Circuit-Switchers) | |
Secondary faults — all other connections of transformers | 4000 (3000A for 115-kV single-gap Circuit-Switchers) | |
Internal faults — see both primary and secondary faults, above |
♥ Depending on continuous rating of Circuit-Switcher.
♣ Will switch magnetizing currents associated with such loads.
♠ Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:
System Voltage, kV | 34.5 thru 69 | 115 and 138 | 161 | 230 | 345 |
---|---|---|---|---|---|
Total Length, Miles | 7 | 15 | 20 | 25 | 40 |
Interrupting Current Ratings for Line Switching and Protection
Mastertrol Mark V Installation Manual Transfer Switch
Class | Qualifications | Maximum Amperes, Interrupting RMS Symmetrical |
---|---|---|
Load Splitting (Parallel or Loop Switching) | Max 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS | 1200/1600/2000♥ |
Load Dropping | Circuits with all load-side transformers connected solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side | 1200/1600/2000♥ |
Circuits with all load-side transformers connected other than as described above. | 1200/1600/2000♥ | |
Line Dropping | Maximum length of line: 300 miles. | |
Fault Interrupting | Line or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than ♠. | 7000 or 8000 |
Line or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher less than ♠. | 4000 (3000A for 115-kV single-gap Circuit-Switchers) |
♥ Depending on continuous rating of Circuit-Switcher.
♠ Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:
System Voltage, kV | 34.5 thru 69 | 115 and 138 | 161 | 230 | 345 |
---|---|---|---|---|---|
Total Length, Miles | 7 | 15 | 20 | 25 | 40 |
Interrupting Current Ratings for Cable Switching and Protection
Class | Qualifications | Maximum Amperes, Interrupting RMS Symmetrical |
---|---|---|
Load Splitting (Parallel or Loop Switching) | Max 60-hertz recovery voltage: 90 kV RMS and 150 kV RMS | 1200/1600/2000♥ |
Load Dropping | Circuits with all load-side transformers connected solidly grounded-wye on the primary (Circuit-Switcher) side and delta on the secondary side | 1200/1600/2000♥ |
Circuits with all load-side transformers connected other than as described above. | 1200/1600/2000♥ | |
Cable Dropping (Charging Current) | Shielded and Unshielded Cable | 550 |
Fault Interrupting | Cable or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than ♠. | 7000 or 8000 |
Cable or bus faults with the total connected length of all lines on the source side of the Circuit-Switcher less than ♠. | 4000 (3000A for 115-kV single-gap Circuit-Switchers) |
♥ Depending on continuous rating of Circuit-Switcher.
♠ Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:
System Voltage, kV | 34.5 thru 69 | 115 and 138 | 161 | 230 | 345 |
---|---|---|---|---|---|
Total Length, Miles | 7 | 15 | 20 | 25 | 40 |
Interrupting Current Ratings for Shunt Capacitor Bank Switching and Protection
Class | Qualifications | Maximum Amperes, Interrupting RMS Symmetrical | |
---|---|---|---|
Bank Current Switching | Grounded capacitor bank | Applications on solidly grounded systems through 69 kV | 1000 |
All other applications | 550 | ||
Ungrounded capacitor bank | 550 | ||
Fault Interrupting | Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher not less than ♠. | 7000 or 8000 | |
Primary faults with the total connected length of all lines on the source side of the Circuit-Switcher less than ♠. | 4000 (3000A for 115-kV single-gap Circuit-Switchers) |
♠ Total connected length of all ovehead lines (in all directions) including any number of feeders connected to source-side substations as indicated in the table below:
System Voltage, kV | 34.5 thru 69 | 115 and 138 | 161 | 230 | 345 |
---|---|---|---|---|---|
Total Length, Miles | 7 | 15 | 20 | 25 | 40 |
Interrupting Current Ratings for Reactor Switching and Protection
Class | Qualifications | Maximum Amperes, Interrupting RMS Symmetrical | |
---|---|---|---|
Series Reactor Switching | Refer to the nearest S&C Sales Office. | ||
Shunt Reactor Switching and Protection (Line-Connected or Tertiary Connected Reactors) | Reactor Current Switching | Reactor wye-connected with solidly grounded neutral | 1000 |
Reactor delta-connected, or wye-connected with ungrounded neutral | 1000 | ||
Fault Interrupting | Oil-insulated reactors | 2800 | |
Air-insulated reactors | 2000 |
For many auto enthusiasts, there is as much enjoyment to be derived from rebuilding, modifying and blueprinting their car's engine as there is in getting behind the wheel and driving it. For those folks, The Motor Bookstore presents the series of Chevy and GM engine manuals covering all aspects of their vehicle's engine, how to maintain it, how to modify it and more. Find information on big-block engine parts, how to build maximum performance engines, small-block engines, how to overhaul V8 engines, rebuilding LS engines and all you need to know about the motors that power muscle cars. These well-written and copiously illustrated manuals run the gamut from vintage engines to modern motors. Order from The Motor Bookstore and get your manuals with next-day shipping.
DIY Engine Rebuild and Repair Manuals
Whether you need to repair or replace a faltering engine, are restoring a classic vehicle or are customizing your favorite ride, our selection of engine repair and engine rebuild manuals are a valuable resource for getting the job done efficiently. You get accurate information that provides a complete overview and introduction to the various engine parts and components, as well as easy-to-follow instructions on how to do virtually any type of procedure.
Our repair and rebuild books come available for working on an extensive variety of engines, for all makes and models of vehicles.
Mastertrol Mark Ii
Within our DIY engine repair manuals, you’ll find in depth explanations and instructions for working on technical aspects of engines and improving power and performance. Engine rebuild manuals provide sharp photos and illustrations that give anyone with the basic tools and the will to learn the ability to take on basic to complex repairs and modifications.
Mastertrol Mark V Installation Manuals
This can mean substantial savings for the do-it-yourselfer by not having to spend hundreds of dollars in labor costs. Our engine repair manuals also greatly benefit professional mechanics by serving as a reliable resource to refer to for the most thorough technical details and specifications.